Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biosci. j. (Online) ; 35(6): 1899-1906, nov./dec. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1049159

RESUMO

The aim of this study was to determine whether a pneumoperitoneum of 10 mmHg combined or not with the Trendelenburg position could lead to significant changes in intraocular pressure (IOP), ocular pressure perfusion (OPP), and cardiorespiratory variables; as well as determine whether a correlation exists between IOP and mean arterial blood pressure (MAP), and/or partial pressure of carbon dioxide in arterial blood (PaCO2) in cats. Animals were allocated in two groups (n=7/group): GC (without inclination) and GTREN (Trendelenburg position). The variables were recorded before (baseline) and during 30 minutes (T5-T30) after insufflation. In GTREN, a reduction in heart rate was observed at T5 and in respiratory rate at T5 and T15. There was an increase in IOP at T5-T30 in comparison to baseline. There was a reduction in potential of hydrogen in arterial blood in both groups at all times in comparison to baseline. Partial pressure of carbon dioxide in arterial blood was increased at T15-T30 in GC and at T5-T30 in GTREN. In conclusion, the pneumoperitoneum of 10mmHg CO2 did not significantly affect IOP or OPP in cats anaesthetised with isofluorane and kept under spontaneous ventilation. However, induced pneumoperitoneum combined with Trendelenburg position resulted in an increase in IOP in cats subjected to the same anaesthetic conditions, but did not affect OPP.


O objetivo deste estudo foi determinar se o pneumoperitônio de 10 mmHg associado, ou não, à posição de Trendelenburg poderia levar a alterações significativas na Pressão Intraocular (PIO), Pressão de Perfusão Ocular (PPO) e variáveis cardiorrespiratórias, bem como determinar se havia correlação entre a PIO e a Pressão Arterial Média (PAM) e/ou Pressão Parcial de Dióxido de Carbono no Sangue Arterial (PaCO2) em gatos. Os animais foram alocados em dois grupos (n = 7/grupo): GC (sem inclinação) e GTREN (posição de Trendelenburg). As variáveis foram registradas antes (linha de base) e durante 30 minutos (T5-T30) após a insuflação. No GTREN, foi observada redução na frequência cardíaca em T5 e, na frequência respiratória, em T5 e T15. Houve aumento da PIO no T5-T30 comparativamente ao valor basal. Houve redução no Potencial de Hidrogênio no sangue arterial em ambos os grupos em todos os momentos comparativamente à linha de base. A Pressão Parcial de Dióxido de Carbono no sangue arterial aumentou em T15-T30 no GC e em T5-T30 no GTREN. Concluiu-se que o pneumoperitônio de 10mmHg CO2 não afetou significativamente a PIO ou a PPO em gatos anestesiados com isofluorano e mantidos sob ventilação espontânea. No entanto, o pneumoperitônio induzido combinado à posição de Trendelenburg resultou em aumento da PIO em gatos submetidos às mesmas condições anestésicas, mas não afetou a PPO.


Assuntos
Pneumoperitônio , Gatos , Laparoscopia , Abscesso Abdominal
2.
Ciênc. rural ; 47(8): e20160757, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839886

RESUMO

ABSTRACT: Long bone fractures are commonly in surgery routine and several bone imobilization techniques are currently available. Technological progress has enabled to use low cost materials in surgical procedures. Thus, the aim of this study was to evaluate the applicability of polyamide 12 rods, solid and hollow in swine femurs, comparing them through flexion strength. This study had as second aim to fix the locking errors, commom place in interlocking nails, once polyamide 12 allows perforation in any direction by orthopaedic screw. Six groups were used: G1 - eight whole swine femurs; G2 - eight whole swine femurs with drilled medullary canal; G3 - two solid polyamide 12 rods; G4 - two hollow polyamide 12 rods; G5 - eight osteotomized drilled swine femurs with a solid polyamide 12 rod implanted in the medullary canal and locked by four 316L stainless steel screws; and G6 - similar to G5 but using hollow rods instead of solid ones. No significant differences were observed for the modulus of rupture between solid and hollow rods, demonstrating that both rods had similar performances. These results led to the speculation that the addition of other polymers to the hollow rods could increase their strength and thus the bone-implant system. Furthermore, the comparison between G1, G5 and G6 could be analyzed using the finite element method in future. New polymeric materials may be developed based on the data from this study, strengthening the bone-implant system and making possible screws to be placed in any direction, nullifying the detrimental forces on the fracture site.


RESUMO: Fraturas em ossos longos são comumente encontradas na rotina cirúrgica e várias técnicas de imobilização óssea estão disponíveis. Com o avanço tecnológico, tornou-se viável utilizar materiais de baixo custo nos procedimentos, portanto esse estudo objetivou avaliar a aplicabilidade de hastes de poliamida 12, sólidas e vazadas, implantadas em fêmures suínos, comparando-as segundo as forças de flexão e aos erros de bloqueio, corriqueiros nesse implante, uma vez que a poliamida 12 permite sua perfuração em qualquer direção por meio de parafusos ortopédicos. Seis grupos foram usados: G1 - oito fêmures suínos íntegros; G2 - oito fêmures suínos, fresados intramedularmente; G3 - duas hastes maciças de poliamida 12; G4 - duas hastes vazadas de poliamida 12; G5 - oito fêmures suínos osteotomizados e fresados, com haste de poliamida 12 maciça implantada no canal medular e bloqueada com quatro parafusos de aço inoxidável 316L e G6 - diferente de G5 apenas por utilizar hastes vazadas. Não foram observadas diferenças significativas no módulo de ruptura entre hastes sólidas e vazadas, demonstrando que ambas apresentaram o mesmo desempenho. Estes resultados levaram à especulação de que adicionar outros polímeros às hastes vazadas aumentaria sua força e, portanto, do sistema osso-implante. Além disso, a comparação entre G1, G5 e G6 poderia no futuro ser analisada utilizando o método dos elementos finitos. Novos polímeros podem ser desenvolvidos baseando-se nos dados deste estudo, reforçando o sistema osso-implante e também possibilitando o uso de perfurações para o bloqueio no transoperatório em qualquer direção, anulando as forças deletérias atuantes no sítio de fratura.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA